Protection contre les fuites boîtier moulé disjoncteur interrupteur d'air EZD-100M 3P 40A 50A 60A 75A 80A 100A Type fixe 380 /400VAC 35KA TMD

USD 58.57USD 62.98

Protection contre les fuites boîtier moulé disjoncteur interrupteur d'air EZD-100M 3P 40A 50A 60A 75A 80A 100A Type fixe 380 /400VAC 35KA TMD

Description
main information
Product Series
EZD
product type
breaker
Product short name
EZD100M
Circuit breaker application
Distribution protection
Number of poles
3P
Protection pole description
3d
Additional information
Leakage current protection
No leakage protection
Rated current [In]
40 A on 40 °C
Circuit breaker model
M
Network Type
AC
Network frequency
50/60 Hz
Control type
handle
Installation type
Fixed
Installation method
Base plate installation
Connection method - upper end
Front connection
Connection method - lower end
Front connection
Rated insulation voltage [Ui]
690 V complies with EN/IEC 60947-2
Rated impulse withstand voltage [Uimp]
6 kV in accordance with EN/IEC 60947-2
Rated working voltage [Ue]
500 V AC 50/60 Hz in accordance with EN/IEC 60947-2
Breaking capacity
10 kA Icu on 500 V AC 50/60 Hz in accordance with EN/IEC 60947-2 
20 kA Icu on 440 V AC 50/60 Hz in accordance with EN/IEC 60947-2 
65 kA Icu on 220/230 V AC 50/60 Hz in accordance with EN/IEC 60947-2 
35 kA Icu 380/400 V AC 50/60 Hz in accordance with EN/IEC 60947-2 
30 kA Icu 415 V AC 50/60 Hz in accordance with EN/ IEC 60947-2
Use category
AC class
Use breaking ability [Ics]
30 kA on 220/230 V AC 50/60 Hz in accordance with EN/IEC 60947-2 
17 kA on 380/400 V AC 50/60 Hz in accordance with EN/IEC 60947-2 
7 kA on 415 V AC 50/60 Hz in accordance with EN/IEC 60947-2 
5 kA on 440 V AC 50/60 Hz in accordance with EN/IEC 60947-2 
3 kA on 500 V AC 50/60 Hz in accordance with EN/IEC 60947-2
Mechanical life
8500 times
Electrical life
4000 times 440 V In in accordance with EN/IEC 60947-2
Phase spacing
25 mm
Trip unit name
TM-D
Trip unit type
Thermal magnetic
Trip unit rating
40 A on 40 °C
Type of protection
Short circuit protection (magnetic protection) 
overload protection (thermal protection)
Long delay current setting type
Fixed
Long delay current setting value [Ir]
1 In
Instantaneous protection current setting type
Fixed
height
130 mm
width
75 mm
depth
60 mm
product weight
0.78 kg
model
EZD100
surroundings
Standards compliant
IEC 60947-2 
EN 60947-2
Pollution level
3 in accordance with IEC 60947-1
Operating temperature
-25...70 °C
Storage ambient temperature
-50...85 °C

Specification

Tripping form : Thermal magnetic

is_customized : Yes

Trip unit : TMD

Operation method : Manual

Trip unit rated current : 40A-100A

Shell current : 100A

Type : Moulded Case

Protective function : LI

Wiring : Board front wiring

Rated voltage : 380/400VAC

Model Number : EZD100M3

+