Protection contre les fuites boîtier moulé disjoncteur interrupteur d'air EZD-100M 3P 40A 50A 60A 75A 80A 100A Type fixe 380 /400VAC 35KA TMD
main information |
Product Series |
EZD |
product type |
breaker |
Product short name |
EZD100M |
Circuit breaker application |
Distribution protection |
Number of poles |
3P |
Protection pole description |
3d |
Additional information |
Leakage current protection |
No leakage protection |
Rated current [In] |
40 A on 40 °C |
Circuit breaker model |
M |
Network Type |
AC |
Network frequency |
50/60 Hz |
Control type |
handle |
Installation type |
Fixed |
Installation method |
Base plate installation |
Connection method - upper end |
Front connection |
Connection method - lower end |
Front connection |
Rated insulation voltage [Ui] |
690 V complies with EN/IEC 60947-2 |
Rated impulse withstand voltage [Uimp] |
6 kV in accordance with EN/IEC 60947-2 |
Rated working voltage [Ue] |
500 V AC 50/60 Hz in accordance with EN/IEC 60947-2 |
Breaking capacity |
10 kA Icu on 500 V AC 50/60 Hz in accordance with EN/IEC 60947-2 |
20 kA Icu on 440 V AC 50/60 Hz in accordance with EN/IEC 60947-2 |
65 kA Icu on 220/230 V AC 50/60 Hz in accordance with EN/IEC 60947-2 |
35 kA Icu 380/400 V AC 50/60 Hz in accordance with EN/IEC 60947-2 |
30 kA Icu 415 V AC 50/60 Hz in accordance with EN/ IEC 60947-2 |
Use category |
AC class |
Use breaking ability [Ics] |
30 kA on 220/230 V AC 50/60 Hz in accordance with EN/IEC 60947-2 |
17 kA on 380/400 V AC 50/60 Hz in accordance with EN/IEC 60947-2 |
7 kA on 415 V AC 50/60 Hz in accordance with EN/IEC 60947-2 |
5 kA on 440 V AC 50/60 Hz in accordance with EN/IEC 60947-2 |
3 kA on 500 V AC 50/60 Hz in accordance with EN/IEC 60947-2 |
Mechanical life |
8500 times |
Electrical life |
4000 times 440 V In in accordance with EN/IEC 60947-2 |
Phase spacing |
25 mm |
Trip unit name |
TM-D |
Trip unit type |
Thermal magnetic |
Trip unit rating |
40 A on 40 °C |
Type of protection |
Short circuit protection (magnetic protection) |
overload protection (thermal protection) |
Long delay current setting type |
Fixed |
Long delay current setting value [Ir] |
1 In |
Instantaneous protection current setting type |
Fixed |
height |
130 mm |
width |
75 mm |
depth |
60 mm |
product weight |
0.78 kg |
model |
EZD100 |
surroundings |
Standards compliant |
IEC 60947-2 |
EN 60947-2 |
Pollution level |
3 in accordance with IEC 60947-1 |
Operating temperature |
-25...70 °C |
Storage ambient temperature |
-50...85 °C |
Tripping form : Thermal magnetic
is_customized : Yes
Trip unit : TMD
Operation method : Manual
Trip unit rated current : 40A-100A
Shell current : 100A
Type : Moulded Case
Protective function : LI
Wiring : Board front wiring
Rated voltage : 380/400VAC
Model Number : EZD100M3